Turn approved facility drawings into an organised, documented installation. Our data-centre facilities scope focuses on racks, containment, pathways, cabling and agreed equipment placement, coordinated with the appointed design and specialist teams.

Discuss your requirements ↗
01
01

Racks & aisle containment

Set out and install racks, doors, panels and approved aisle-containment components. Check alignment, access clearance, equipment mounting and asset identifiers against the approved layout.

Project output

Rack installation checklist and location register.

02

Pathways & structured cabling

Install trays, baskets, fibre/copper links and patching according to the approved routing and segregation details. Maintain identification and test evidence from origin to destination.

Project output

Cable schedule, test reports and route mark-ups.

03

Equipment & power interfaces

Mount specified rack PDUs and agreed equipment; coordinate power, earthing, cooling and fire-system interfaces with authorised specialists. Energisation and specialist commissioning follow their approved procedures.

Project output

Installation records and specialist interface checklist.

04

Installation quality & closeout

Raise inspection requests, record concealed works before closure and resolve installation snags. Reconcile labels, equipment locations and redline drawings into a structured handover pack.

Project output

Inspection evidence, snag closure and as-built inputs.

02

Aisle containment

Physical separation of hot and cold airflow paths around racks. The selected arrangement follows the approved thermal and facility design.

Rack PDU

A rack power distribution unit supplies equipment connections and may provide metering or switching. Ratings and A/B supply arrangements follow the approved electrical design.

As-built records

Drawings and schedules updated to reflect the actual installation. They should reconcile asset labels, routes, approved changes and test records.

03

Illustrative patterns for project discussions. Final topology, sizing, products and acceptance criteria are developed against your requirements. These are BrightGate concept diagrams, not vendor-certified designs.

Rack-row installation concept
Rack-row installation conceptA simplified installation view showing overhead pathways, rack positions and coordinated power interfaces. Dimensions, cooling arrangement and electrical design come from the approved project drawings. This service covers installation, not facility design, certification, operation or maintenance.BRIGHTGATE / SOLUTION ENGINEERINGREFERENCE ARCHITECTUREApproved routesAisle containmentRack ARack BRack CABA / B power interfacesConcept view · final sizing and topology follow the agreed project scope

On smaller screens, scroll the diagram sideways to see all components.

Solid: main relationship or sequenceDashed: supporting, control or feedback relationship

A simplified installation view showing overhead pathways, rack positions and coordinated power interfaces. Dimensions, cooling arrangement and electrical design come from the approved project drawings. This service covers installation, not facility design, certification, operation or maintenance.

Design practices to apply

  • Confirm floor loading and access before delivery.
  • Preserve approved power/data segregation.
  • Keep installation records traceable to each rack.
04

Examples to evaluate during scoping. Selection, supported features, hardware and licences depend on the agreed solution; a product mention does not imply a certification or an included purchase.

Fibre / copper & cable containment

Install the scheduled materials against approved routes and project specifications.

05

Acceptance evidence

Physical installation

Check rack positions, clearances, fixing and labels against approved drawings.

Cabling

Match tested links to the cable and port schedules.

Closeout

Reconcile inspection requests, specialist interfaces and resolved snags.

View the complete capability checklist
  • Racks, cabinets and hot / cold aisle containment installation
  • Overhead trays, fibre raceways and cable management
  • Power-distribution units and approved electrical connections
  • UPS and power equipment installation within approved design
  • Cooling equipment and associated pipe / duct installation
  • Earthing, bonding and equipment identification
  • Environmental sensor and monitoring-device installation
  • Installation inspections, coordination and as-built handover